How Tally 2.0 Builds a Model
Tally 2.0 reads quantities from your Revit model. The Object of Study sets what Tally 2.0 reads, and each material's definition sets how Tally 2.0 turns its geometry into quantities.
Object of Study
Section titled “Object of Study”- Categories. Ceilings, Curtainwall Mullions, Curtainwall Panels, Doors, Floors, Railings, Roofs, Stairs, Structure, Walls and Windows. Tally 2.0 does not read mechanical, electrical or plumbing elements.
- Worksets. Select the user worksets to include.
- Phases. Tally 2.0 reads elements by the phase they were created in. To count the savings from an existing building you reuse, include the phase named Existing.
- Linked models. Tally 2.0 lists your model and its linked models. Select the links, worksets and phases to include from each.
Study types
Section titled “Study types”- Full Building Study. The whole building, using primary design options.
- Design Option Comparison. Compares at least two Revit design options. Tally 2.0 reads only the elements in the selected options. The order you select them in is the order of the results.
- Full Building Comparison. Compares at least two design options, each with the rest of the building included.
- Define Template. Creates virtual elements for every family in the model, so you can set definitions in a template file before anything is placed.
Design options come from your own model. Linked models use their main model only.
Takeoff methods
Section titled “Takeoff methods”A takeoff method turns what Revit measures into a mass of material: by area, length, spacing or volume, combined with a density, thickness, cross section or factor. Tally 2.0 offers the methods that fit what Revit measures for the element and the material. See Assigning Materials.
Reference service life
Section titled “Reference service life”Tally 2.0 assesses the building over a fixed reference service life of 60 years, the same as C.Scale. Materials with a shorter service life are replaced within that period.
Set Reuse in a definition to account for reused materials. Existing to Remain removes the material's product, transport and construction emissions (A1–A5). Salvaged removes its product emissions (A1–A3) and keeps transport and construction.